Home Standby Power
8kW &
10kW Standby Generators
Restoring Power with
Confidence
Reliable Protection for Your Home and Investment
Eaton’s 8 and 10kW Standby Generators boast 410cc and530cc
engines. These units are perfect for automatically backing up
emergency circuits such as refrigerators, furnace fans, sump pumps,
water pumps, or other types of loads that you could not
do without during a power outage.
Features:
• User friendly controller
• Flexible fuel line connector
• Composite mounting pad
• Natural gas or LP gas operation (field convertible)
• Superior harmonics allow flawless operation of sensitive
electronics such as
computers
• Best in class service network allows for piece of mind
| GENERATOR |
EGEN8 (8
kW) |
EGEN10 (10 kW) |
| Rated Maximum
Continuous Power Capacity (LP) |
8,000 Watts* |
10,000 Watts* |
| Rated Maximum
Continuous Power Capacity (NG) |
7,000 Watts* |
9,000 Watts* |
| Rated Voltage |
120/240 |
120/240 |
| Rated Maximum
Continuous Load Current 240 Volts |
33.3 LP/29.2 NG |
41.6 LP/37.5 NG |
| Phase |
1 |
1 |
| Number of Rotor
Poles |
2 |
2 |
| Rated AC Frequency |
60Hz |
60Hz |
| Power Factor |
1 |
1 |
| Battery
Specifications (not included) |
Group 26R
12 Volts and 350 Cold-cranking Amperes Minimum |
Group 26R
12 Volts and 525
Cold-cranking
Amperes
Minimum |
| Unit Weight |
340 Pounds |
387 Pounds |
| Dimensions (L" x W"
x H ") |
48 x 25 x 29 |
48 x 25 x 29 |
| Sound output in
dB(A) at 23 ft. |
62 |
63 |
| ENGINE |
EGEN8 (8
kW) |
EGEN10 (10
kW) |
| Type of Engine |
OHVI |
OHVI V-TWIN |
| Number of Cylinders |
1 |
2 |
| Displacement |
410cc |
530cc |
| Cylinder Block |
Aluminum w/ Cast
Iron Sleeve |
Aluminum w/
Cast
Iron Sleeve |
| Oil
Capacity Including Filter |
Approx.
1.5 Qts. |
Approx.
1.7 Qts. |
| Operating RPM |
3,600 |
3,600 |
| Fuel
Consumption |
|
|
Natural
Gas
cu.ft./hr.
1/2 Load
Full Load |
77
139 |
102
156 |
Liquid
Propane ft3/hr
(gal/hr)
1/2 Load
Full Load |
34 (0.94)
62 (1.68) |
46 (1.25)
70 (1.93) |
Required fuel pressure to generator fuel inlet at all load
ranges
-5 to 7 inches of water column for natural gas, 10 to 12
inches of water column for LP gas |
|
|
| CONTROLS
(8kW & 10kW) |
|
| 2-Line Plain Text
LCD Display |
Simple user interface for ease of
operation |
| Mode Switch |
|
| -Auto |
Automatic Start on Utility failure. 7 day
exerciser |
| -Off |
Stops unit. Power is removed. Control
and charger still operate. |
|
-Manual/Test (start) |
Start with starter
control, unit stays on. If
utility fails, transfer to load takes place. |
Automatic Voltage
Regulator
w/ Overvoltage Protection |
Standard |
| Automatic Low Oil
Pressure Shutdown |
Standard |
| Overspeed Shutdown |
Standard, 72 Hz |
| High Temperature
Shutdown |
Standard |
| Overcrank Protection |
Standard |
| Safety Fuse |
Standard |
50A
Transfer Switch Improvements & Enhancements
The EGS50L12 and EGS50L12R will supersede the CHGEN50ATS
and CHGEN50ATSR respectively. The following information highlights
the changes and improvements made with the new design.
• Improved Contactor with Enclosed Contacts
Power switching contacts are completely enclosed and barrier
included isolating from
panel interior section for added safety.
• Easily Visible Service Information
A label has been added with contact number for our service hotline,
to eliminate questions on where to go for aftermarket support.
• Load-Shed Contacts Included
The RTC-50 controller includes two sets of contacts for customer use
in shedding load while under generator power. The contacts are
closed when the transfer switch is in utility position and are open
when the transfer switch is in generator position. These
contacts were previously offered as an optional kit.
• New Maintenance Indicator Contacts
The RTC-50 includes contacts for wiring a service indicator
light. A 5mm panel-mount LED with a maximum current rating of 25mA
is recommended (Dialight 559-5101-007F or equivalent). The board
will keep track of the number of hours that the generator has run\
for up to 1000 hours. Each long flash on the indicator light equals
100hrs of run time and each short flash equals 25hrs of run time.
• Cold-Weather Setting for TDNE
Time Delay Normal (Utility) to Emergency (Generator) is selectable
with movement of a jumper. Product is shipped with a delay of 20
seconds and may be changed to 50 seconds for allow for smooth
startup in cold-weather climates.
• New Go-To-Generator Contacts
Board includes contacts which allow for acceptance of a remote “go
to generator”
signal. Upon receiving this signal from any remote source, the
contactor will switch to emergency position if the generator source
is available (i.e. if the generator is running and available).
|
 |